Grain Auger
First make your selection below stating whether your grain auger has a fan or not, then select the motor starter.
After these selections you will be left with either Roto-Con, Rotoverter Type C, or Rotoverter Type D.
Roto-Con units can be filtered from the remaining attributes.
--------------------------------------------------------
When sizing Rotoverter Type C and D
1. Make note of the largest single motor HP.
2. Add the total HP of all motors and devide that number by half.
3. If total HP divided by half, is less than the largest single motor HP, then use the total HP as is and select that value below. If the total HP divided by half, is equal or greater than the largest single motor HP, then select the next Total HP value below. Note: If the total HP divided by half is far greater than the largest single motor HP, then use the total HP divided by half value to select Total HP below.
Note:
- If your motor has a soft starter, please call our sales team at 800-221-7665.
- If starting under load, Size up for Roto-Con, If not under load than size for size.